PC 3010 NT VARIO selectVARIO® chemistry pumping unit
Overview
- VACUU·SELECT vacuum controller with graphical user interface and predefined applications simplifies work in the laboratory
- automatic boiling point detection and adjustment of the vacuum for short process times
- ideal for evaporation of large amounts of high-boiling solvents even at low temperatures
- extraordinary diaphragm life for minimum operational and servicing costs
- excellent environmental compatibility through low energy consumption and efficient solvent recovery
Ultimate vacuum
0.6 mbar
Ultimate vacuum with gas ballast
1.2 mbar
Max. pumping speed 50 Hz
12.8 m3/h
VARIO® chemistry pumping unit in action
The PC 3010 NT VARIO select pumping unit precisely controls the vacuum level in order to achieve unparalleled process control. With its combination of high pumping speed and fractional millibar ultimate vacuum, this pump is suitable for demanding applications with even high boiling point solvents at low tempartures. This pump is regularly used to support floor-standing rotary evaporators, vacuum drying ovens, distillation columns, and other similar work in miniplants, kilo labs, and scale-up facilities. The integrated VACUU·SELECT controller provides an easy-to-use, application based interface that covers all common lab applications. The VACUU·SELECT controller has you covered. Use manual set-point-control for simple processes, run fully automated distillations, or create your own application with simple drag-and-drop editing. For solvent evaporation, the VACUU·SELECT controller continuously detects the boiling point and automatically adjusts the vacuum process as necessary. In addition, the VARIO control algorithm maintains the desired vacuum level by running the motor only as fast as necessary. This prevents bumping and foaming, makes the pump whisper quiet, and extends maintenance intervals. The inlet separator, made of glass with a robust protective coating, prevents particles and liquid droplets from entering the pump, preventing damage and extending pump life. And the exhaust vapor condenser allows for nearly complete recovery of solvents when used with a chilled water line or recirculating chiller for economical recycling and environmental protection. #
Technical data and graphs
Max. pumping speed 50 Hz | 12.8 m3/h | Select diagram |
Max. pumping speed 60 Hz | 7.5 cfm | Select diagram |
Ultimate vacuum | 0.6 mbar / 0.45 torr | |
Ultimate vacuum with gas ballast | 1.2 mbar / 0.9 torr | |
Number of heads | 8 | |
Number of stages | 4 | |
Vacuum controller | VACUU·SELECT | |
Lower ambient temperature (operation) | 10 °C | |
Upper ambient temperature (operation) | 40 °C | |
Lower ambient temperature (storage) | -10 °C | |
Upper ambient temperature (storage) | 60 °C | |
Max. back pressure (abs.) | 1.1 bar | |
Inlet connection | Small flange KF DN 25 / hose nozzle DN 15 mm | |
Outlet connection | Hose nozzle DN 8-10 mm | |
Coolant connection | 2 x hose nozzle DN 6-8 mm | |
Rated motor power | 0.53 kW | |
Protection class IEC 60529 | IP 40 | |
Dimension L in mm | 616 mm | |
Dimension B in mm | 387 mm | |
Dimension H in mm | 450 mm | |
Weight | 29.7 kg | |
Noise (sound pressure level) in dBA at 50 Hz or 1500 rpm/62% (VARIO)/1500 rpm (VARIO-SP)/12500 Upm (VACUU·PURE®) | 47 dBA | |
ATEX conformity | II 3/- G Ex h IIC T3 Gc X Internal Atm. only | |
NRTL certification | No | |
Items supplied | Pumping unit completely mounted, ready for use, with manual. | |
Rated mains voltage range 1 | 200-230 V | |
Mains frequency 1 | 50-60 Hz |
für Zoom klicken
Max. pumping speed 50 Hz
für Zoom klicken
Max. pumping speed 60 Hz
für Zoom klicken
Pump down graph 50 Hz (100 l volume)
für Zoom klicken
Pump down graph 60 Hz (100 l volume)
Downloads
Equipment
VARIO® chemistry pumping unit in action
The PC 3010 NT VARIO select pumping unit precisely controls the vacuum level in order to achieve unparalleled process control. With its combination of high pumping speed and fractional millibar ultimate vacuum, this pump is suitable for demanding applications with even high boiling point solvents at low tempartures. This pump is regularly used to support floor-standing rotary evaporators, vacuum drying ovens, distillation columns, and other similar work in miniplants, kilo labs, and scale-up facilities. The integrated VACUU·SELECT controller provides an easy-to-use, application based interface that covers all common lab applications. The VACUU·SELECT controller has you covered. Use manual set-point-control for simple processes, run fully automated distillations, or create your own application with simple drag-and-drop editing. For solvent evaporation, the VACUU·SELECT controller continuously detects the boiling point and automatically adjusts the vacuum process as necessary. In addition, the VARIO control algorithm maintains the desired vacuum level by running the motor only as fast as necessary. This prevents bumping and foaming, makes the pump whisper quiet, and extends maintenance intervals. The inlet separator, made of glass with a robust protective coating, prevents particles and liquid droplets from entering the pump, preventing damage and extending pump life. And the exhaust vapor condenser allows for nearly complete recovery of solvents when used with a chilled water line or recirculating chiller for economical recycling and environmental protection. #
Technical data and graphs
Max. pumping speed 50 Hz | 12.8 m3/h | Select diagram |
Max. pumping speed 60 Hz | 7.5 cfm | Select diagram |
Ultimate vacuum | 0.6 mbar / 0.45 torr | |
Ultimate vacuum with gas ballast | 1.2 mbar / 0.9 torr | |
Number of heads | 8 | |
Number of stages | 4 | |
Vacuum controller | VACUU·SELECT | |
Lower ambient temperature (operation) | 10 °C | |
Upper ambient temperature (operation) | 40 °C | |
Lower ambient temperature (storage) | -10 °C | |
Upper ambient temperature (storage) | 60 °C | |
Max. back pressure (abs.) | 1.1 bar | |
Inlet connection | Small flange KF DN 25 / hose nozzle DN 15 mm | |
Outlet connection | Hose nozzle DN 8-10 mm | |
Coolant connection | 2 x hose nozzle DN 6-8 mm | |
Rated motor power | 0.53 kW | |
Protection class IEC 60529 | IP 40 | |
Dimension L in mm | 616 mm | |
Dimension B in mm | 387 mm | |
Dimension H in mm | 450 mm | |
Weight | 29.7 kg | |
Noise (sound pressure level) in dBA at 50 Hz or 1500 rpm/62% (VARIO)/1500 rpm (VARIO-SP)/12500 Upm (VACUU·PURE®) | 47 dBA | |
ATEX conformity | II 3/- G Ex h IIC T3 Gc X Internal Atm. only | |
NRTL certification | No | |
Items supplied | Pumping unit completely mounted, ready for use, with manual. | |
Rated mains voltage range 1 | 200-230 V | |
Mains frequency 1 | 50-60 Hz |
für Zoom klicken
Max. pumping speed 50 Hz
für Zoom klicken
Max. pumping speed 60 Hz
für Zoom klicken
Pump down graph 50 Hz (100 l volume)
für Zoom klicken