PC 610 selectChemistry pumping unit
Overview
- VACUU·SELECT vacuum controller with graphical user interface simplifies work in the laboratory
- predefined applications save time and give reproducible results
- easy-to-use application editor allows own process sequences
- meets high vacuum requirements for most high boiling solvents
- excellent environmental friendliness due to efficient solvent recovery
Ultimate vacuum
1.5 mbar
Ultimate vacuum with gas ballast
3 mbar
Max. pumping speed 50 Hz
3.4 m3/h
Chemistry pumping unit in action
Our PC 600-series chemistry pumping units of this series are an excellent choice for supporting electronically controlled evaporation or drying processes with even many high boiling point solvents. Our popular MD 4C NT three-stage chemistry diaphragm pump, with its 2 mbar ultimate vacuum rating, is the heart of these pumping units. Typical applications include lab applications such as rotary evaporation, vacuum drying ovens, and vacuum distillation. The integrated VACUU·SELECT controller provides an easy-to-use, application based interface that covers all common lab applications. The VACUU·SELECT controller has you covered. Use manual set-point-control for simple processes, run distillations, or create your own application with simple drag-and-drop editing. For solvent evaporation, it constantly monitors the pressure and switches to 2 point control mode to hold the pressure stable when a boiling point is detected. The controller also allows for easy manual vacuum control for simple processes. The inlet separator, made of glass with protective coating, prevents particles and liquid droplets from entering the pump. The exhaust vapor condenser provides nearly 100% recovery of solvents for economical recycling and environmental protection.
Technical data and graphs
Max. pumping speed 50 Hz | 3.4 m3/h | Select diagram |
Max. pumping speed 60 Hz | 2.2 cfm | Select diagram |
Ultimate vacuum | 1.5 mbar / 1.1 torr | |
Ultimate vacuum with gas ballast | 3 mbar / 2.2 torr | |
Number of heads | 4 | |
Number of stages | 3 | |
Vacuum controller | VACUU·SELECT | |
Lower ambient temperature (operation) | 10 °C | |
Upper ambient temperature (operation) | 40 °C | |
Lower ambient temperature (storage) | -10 °C | |
Upper ambient temperature (storage) | 60 °C | |
Max. outlet pressure (abs.) | 1.1 bar | |
Inlet connection | Hose nozzle DN 8-10 mm | |
Outlet connection | Hose nozzle DN 8-10 mm | |
Coolant connection | 2 x hose nozzle DN 6-8 mm | |
Rated motor power | 0.25 kW | |
Rated motor speed at 50/60 Hz | 1500/1800 min-1 | |
Protection class IEC 60529 | IP 20 | |
Dimension L in mm | 419 mm | |
Dimension B in mm | 243 mm | |
Dimension H in mm | 457 mm | |
Weight | 20.4 kg | |
Noise (sound pressure level) in dBA at 50 Hz or 1500 rpm/62% (VARIO)/1500 rpm (VARIO-SP)/12500 Upm (VACUU·PURE®) | 45 dBA | |
NRTL certification | No | |
Items supplied | Pumping unit completely mounted, ready for use, with manual. | |
Rated mains voltage range 1 | 100-115 V | |
Rated mains voltage range 2 | 120 V | |
Mains frequency 1 | 50-60 Hz | |
Mains frequency 2 | 60 Hz | |
Interface | Ethernet (RJ45): Modbus TCP / USB (Type A): Data transfer, software update, RS-232 (additional adapter required) |
für Zoom klicken
Max. pumping speed 50 Hz
für Zoom klicken
Max. pumping speed 60 Hz
für Zoom klicken
Pump down graph 50 Hz (10 l volume)
für Zoom klicken
Pump down graph 60 Hz (10 l volume)
Downloads
Equipment
Chemistry pumping unit in action
Our PC 600-series chemistry pumping units of this series are an excellent choice for supporting electronically controlled evaporation or drying processes with even many high boiling point solvents. Our popular MD 4C NT three-stage chemistry diaphragm pump, with its 2 mbar ultimate vacuum rating, is the heart of these pumping units. Typical applications include lab applications such as rotary evaporation, vacuum drying ovens, and vacuum distillation. The integrated VACUU·SELECT controller provides an easy-to-use, application based interface that covers all common lab applications. The VACUU·SELECT controller has you covered. Use manual set-point-control for simple processes, run distillations, or create your own application with simple drag-and-drop editing. For solvent evaporation, it constantly monitors the pressure and switches to 2 point control mode to hold the pressure stable when a boiling point is detected. The controller also allows for easy manual vacuum control for simple processes. The inlet separator, made of glass with protective coating, prevents particles and liquid droplets from entering the pump. The exhaust vapor condenser provides nearly 100% recovery of solvents for economical recycling and environmental protection.
Technical data and graphs
Max. pumping speed 50 Hz | 3.4 m3/h | Select diagram |
Max. pumping speed 60 Hz | 2.2 cfm | Select diagram |
Ultimate vacuum | 1.5 mbar / 1.1 torr | |
Ultimate vacuum with gas ballast | 3 mbar / 2.2 torr | |
Number of heads | 4 | |
Number of stages | 3 | |
Vacuum controller | VACUU·SELECT | |
Lower ambient temperature (operation) | 10 °C | |
Upper ambient temperature (operation) | 40 °C | |
Lower ambient temperature (storage) | -10 °C | |
Upper ambient temperature (storage) | 60 °C | |
Max. outlet pressure (abs.) | 1.1 bar | |
Inlet connection | Hose nozzle DN 8-10 mm | |
Outlet connection | Hose nozzle DN 8-10 mm | |
Coolant connection | 2 x hose nozzle DN 6-8 mm | |
Rated motor power | 0.25 kW | |
Rated motor speed at 50/60 Hz | 1500/1800 min-1 | |
Protection class IEC 60529 | IP 20 | |
Dimension L in mm | 419 mm | |
Dimension B in mm | 243 mm | |
Dimension H in mm | 457 mm | |
Weight | 20.4 kg | |
Noise (sound pressure level) in dBA at 50 Hz or 1500 rpm/62% (VARIO)/1500 rpm (VARIO-SP)/12500 Upm (VACUU·PURE®) | 45 dBA | |
NRTL certification | No | |
Items supplied | Pumping unit completely mounted, ready for use, with manual. | |
Rated mains voltage range 1 | 100-115 V | |
Rated mains voltage range 2 | 120 V | |
Mains frequency 1 | 50-60 Hz | |
Mains frequency 2 | 60 Hz | |
Interface | Ethernet (RJ45): Modbus TCP / USB (Type A): Data transfer, software update, RS-232 (additional adapter required) |
für Zoom klicken
Max. pumping speed 50 Hz
für Zoom klicken
Max. pumping speed 60 Hz
für Zoom klicken
Pump down graph 50 Hz (10 l volume)
für Zoom klicken