Cat.-No. Volume range Model Accuracy in % (±) Accuracy in µl (±) Coefficient of variation (%) Coefficient of variation (µl) Recommended tip size Number of channels
705900 0.5 - 10 µl M8-10 1.6 % 0.16 µl 1 % 0.1 µl 0,5 - 20 8-channel
705906 5 - 50 µl M8-50 0.8 % 0.4 µl 0.4 % 0.2 µl 2 - 200 8-channel
705908 10 - 100 µl M8-100 0.8 % 0.8 µl 0.3 % 0.3 µl 2 - 200 8-channel
705910 20 - 200 µl M8-200 0.8 % 1.6 µl 0.3 % 0.6 µl 2 - 200 8-channel
705912 30 - 300 µl M8-300 0.6 % 1.8 µl 0.3 % 0.9 µl 5 - 300 8-channel
Grouped product items
Price per Price
1 piece(s) $ 906.00

Inquire

1 piece(s) $ 906.00

Inquire

1 piece(s) $ 906.00

Inquire

1 piece(s) $ 906.00

Inquire

1 piece(s) $ 906.00

Inquire

Product Detail

The Transferpette® S air displacement pipette allows you to work efficiently and ergonomically with both small and large volumes. Low operating forces and a short stroke ensure relaxed pipetting, even during long pipetting series. Due to its perfect ergonomics, the Transferpette® S provides a comfortable grip in any hand position, whether you are right- or left-handed, or have big or small hands. Changing your grip is not necessary, since the microliter pipette provides true one-hand operation: set the volume, pipette, eject the tip.
The volume-change protection is also easy to operate with gloves on and protects your set volume against accidental adjustment. The Transferpette® S also features Easy Calibration technology, which makes calibration a breeze. Calibration can be carried out without tools. A compatibility table shows which tips fit which device, so that you always order the correct pipette tips.
Limitations of use:

Operating temperature of instrument and reagent should be between +15 °C and +40 °C (59 °F to 104 °F) (other temperatures upon request)

Vapor pressure up to 500 mbar

Viscosity: 260 mPa s

For viscous media, the speed must be adjusted if necessary.

Items supplied

Transferpette® S -8, supplied with performance certificate, 2 x TipBox, filled with pipette tips from BRAND, shelf mount, reagent reservoir, installation tool, silicone grease and 1 set of sealing rings

für Zoom klicken

Videos

Youtube preview image
Grouped product items
Cat.-No. Volume range Model Accuracy in % (±) Accuracy in µl (±) Coefficient of variation (%) Coefficient of variation (µl) Recommended tip size Number of channels
705900 0.5 - 10 µl M8-10 1.6 % 0.16 µl 1 % 0.1 µl 0,5 - 20 8-channel
705906 5 - 50 µl M8-50 0.8 % 0.4 µl 0.4 % 0.2 µl 2 - 200 8-channel
705908 10 - 100 µl M8-100 0.8 % 0.8 µl 0.3 % 0.3 µl 2 - 200 8-channel
705910 20 - 200 µl M8-200 0.8 % 1.6 µl 0.3 % 0.6 µl 2 - 200 8-channel
705912 30 - 300 µl M8-300 0.6 % 1.8 µl 0.3 % 0.9 µl 5 - 300 8-channel
Grouped product items
Price per Price
1 piece(s) $ 906.00

Inquire

1 piece(s) $ 906.00

Inquire

1 piece(s) $ 906.00

Inquire

1 piece(s) $ 906.00

Inquire

1 piece(s) $ 906.00

Inquire

Product Detail

The Transferpette® S air displacement pipette allows you to work efficiently and ergonomically with both small and large volumes. Low operating forces and a short stroke ensure relaxed pipetting, even during long pipetting series. Due to its perfect ergonomics, the Transferpette® S provides a comfortable grip in any hand position, whether you are right- or left-handed, or have big or small hands. Changing your grip is not necessary, since the microliter pipette provides true one-hand operation: set the volume, pipette, eject the tip.
The volume-change protection is also easy to operate with gloves on and protects your set volume against accidental adjustment. The Transferpette® S also features Easy Calibration technology, which makes calibration a breeze. Calibration can be carried out without tools. A compatibility table shows which tips fit which device, so that you always order the correct pipette tips.
Limitations of use:

Operating temperature of instrument and reagent should be between +15 °C and +40 °C (59 °F to 104 °F) (other temperatures upon request)

Vapor pressure up to 500 mbar

Viscosity: 260 mPa s

For viscous media, the speed must be adjusted if necessary.