VV 6Solenoid-operated valves

Overview

  • high operating cycles
  • significantly better long term tightness even after long operating time
  • easy to clean
  • versatile connection alternatives via small flange or hose nozzle
  • low leakage rate
Cat. No.
20674090
Upon Request $570.00
- +

Inquire

Solenoid-operated valves in action

In-line isolation valve VV 6, 24 V/=, FPM/PP

These straight-through valves with electromagnetic (solenoid) drive are used for operating cycles with short intervals and, therefore, are often used as vacuum control valves. The straightforward design provides a valve with low leakage rate. The valves in version VV C are made of materials with excellent chemical resistance. The valve sealing of the VV-B 6C is made of a special fluoroelastomer with better form stability than common PTFE, much higher chemical resistance than FKM and excellent long-term leak tightness characteristics.

für Zoom klicken

Technical data and graphs

Upper ambient temperature (operation) 50 °C
Lower ambient temperature (operation) 0 °C
Max. gas temperature 80 °C
Flange connection Small flange KF DN 16 or hose nozzle DN 6/10 mm
Operation Solenoid 24 V/=
Leakage rate 1 x 10-5 mbar l/s
Max. switching frequency 120 pro Min.
Fitting length between flanges 100 mm

Downloads

In-line isolation valve VV 6, 24 V/=,FPM/PP
VV 6 Solenoid-operated valves
Brochure
Brochure PDF 1.4 MB 1.2 MB
Download Download

Related Products

Solenoid-operated valves in action

In-line isolation valve VV 6, 24 V/=, FPM/PP

These straight-through valves with electromagnetic (solenoid) drive are used for operating cycles with short intervals and, therefore, are often used as vacuum control valves. The straightforward design provides a valve with low leakage rate. The valves in version VV C are made of materials with excellent chemical resistance. The valve sealing of the VV-B 6C is made of a special fluoroelastomer with better form stability than common PTFE, much higher chemical resistance than FKM and excellent long-term leak tightness characteristics.

für Zoom klicken

Technical data and graphs

Upper ambient temperature (operation) 50 °C
Lower ambient temperature (operation) 0 °C
Max. gas temperature 80 °C
Flange connection Small flange KF DN 16 or hose nozzle DN 6/10 mm
Operation Solenoid 24 V/=
Leakage rate 1 x 10-5 mbar l/s
Max. switching frequency 120 pro Min.
Fitting length between flanges 100 mm

Downloads

In-line isolation valve VV 6, 24 V/=,FPM/PP
VV 6 Solenoid-operated valves
Brochure
Brochure PDF 1.4 MB 1.2 MB
Download Download