PC 3001 VARIO select TEVARIO® chemistry pumping unit
Overview
- dry ice condenser at the pump exhaus, no cooling water connection required
- simplify lab work with the VACUU·SELECT vacuum controller with graphic user interface and predefined applications
- automatic boiling point detection and continuous optimization of vacuum levels for quick process times, whisper quiet and ultra low vibration
- compact and powerful; superior performance even with continuous condensate purge
- eco-friendly: extremely low power consumption and efficient solvent recovery. Oil-free!
Ultimate vacuum
2.0 mbar
Ultimate vacuum with gas ballast
4 mbar
Max. pumping speed 50 Hz
2 m3/h
VARIO® chemistry pumping unit in action
The PC 3001 VARIO select pumping unit precisely controls the vacuum level in order to achieve unparalleled process control. This pump is suitable for even high boiling point solvents. The integrated VACUU·SELECT controller provides an easy-to-use, application based interface that covers all common lab applications. The VACUU·SELECT controller has you covered. Use manual set-point-control for simple processes, run fully automated distillations, or create your own application with simple drag-and-drop editing. For solvent evaporation, the VACUU·SELECT controller detects solvent boiling and automatically adjusts the pump's motor speed to maintain process control. The VARIO motor speed control also makes the pump whisper quiet and provides for exceptionally long maintenance intervals. The inlet separator, made of glass with a robust protective coating, prevents particles and liquid droplets from entering the pump, preventing damage and extending pump life. The PC 3001 VARIO select TE is equiped with a dry ice condenser at the pump exhaust, so that no cooling water connection is required.
Technical data and graphs
Max. pumping speed 50 Hz | 2 m3/h | Select diagram |
Max. pumping speed 60 Hz | 1.18 cfm | |
Ultimate vacuum | 2.0 mbar / 1.5 torr | |
Ultimate vacuum with gas ballast | 4 mbar / 3 torr | |
Number of heads | 4 | |
Number of stages | 3 | |
Vacuum controller | VACUU·SELECT | |
Lower ambient temperature (operation) | 10 °C | |
Upper ambient temperature (operation) | 40 °C | |
Lower ambient temperature (storage) | -10 °C | |
Upper ambient temperature (storage) | 60 °C | |
Max. back pressure (abs.) | 1.1 bar | |
Inlet connection | Hose nozzle DN 6-10 mm | |
Outlet connection | Hose nozzle DN 8-10 mm | |
Coolant connection | 2 x hose nozzle DN 6-8 mm | |
Rated motor power | 0.16 kW | |
Protection class IEC 60529 | IP 20 | |
Dimension L in mm | 301 mm | |
Dimension B in mm | 341 mm | |
Dimension H in mm | 493 mm | |
Weight | 8.7 kg | |
Noise (sound pressure level) in dBA at 50 Hz or 1500 rpm/62% (VARIO)/1500 rpm (VARIO-SP)/12500 Upm (VACUU·PURE®) | 42 dBA | |
NRTL certification | Yes | |
Items supplied | Pumping unit completely mounted, ready for use, with manual. | |
Rated mains voltage range 1 | 200-230 V | |
Rated mains voltage range 2 | 100-120 V | |
Mains frequency 1 | 50-60 Hz | |
Mains frequency 2 | 50-60 Hz | |
Interface | Ethernet (RJ45): Modbus TCP / USB (Type A): Data transfer, software update, RS-232 (additional adapter required) |
Downloads
Equipment
Application examples
VARIO® chemistry pumping unit in action
The PC 3001 VARIO select pumping unit precisely controls the vacuum level in order to achieve unparalleled process control. This pump is suitable for even high boiling point solvents. The integrated VACUU·SELECT controller provides an easy-to-use, application based interface that covers all common lab applications. The VACUU·SELECT controller has you covered. Use manual set-point-control for simple processes, run fully automated distillations, or create your own application with simple drag-and-drop editing. For solvent evaporation, the VACUU·SELECT controller detects solvent boiling and automatically adjusts the pump's motor speed to maintain process control. The VARIO motor speed control also makes the pump whisper quiet and provides for exceptionally long maintenance intervals. The inlet separator, made of glass with a robust protective coating, prevents particles and liquid droplets from entering the pump, preventing damage and extending pump life. The PC 3001 VARIO select TE is equiped with a dry ice condenser at the pump exhaust, so that no cooling water connection is required.
Technical data and graphs
Max. pumping speed 50 Hz | 2 m3/h | Select diagram |
Max. pumping speed 60 Hz | 1.18 cfm | |
Ultimate vacuum | 2.0 mbar / 1.5 torr | |
Ultimate vacuum with gas ballast | 4 mbar / 3 torr | |
Number of heads | 4 | |
Number of stages | 3 | |
Vacuum controller | VACUU·SELECT | |
Lower ambient temperature (operation) | 10 °C | |
Upper ambient temperature (operation) | 40 °C | |
Lower ambient temperature (storage) | -10 °C | |
Upper ambient temperature (storage) | 60 °C | |
Max. back pressure (abs.) | 1.1 bar | |
Inlet connection | Hose nozzle DN 6-10 mm | |
Outlet connection | Hose nozzle DN 8-10 mm | |
Coolant connection | 2 x hose nozzle DN 6-8 mm | |
Rated motor power | 0.16 kW | |
Protection class IEC 60529 | IP 20 | |
Dimension L in mm | 301 mm | |
Dimension B in mm | 341 mm | |
Dimension H in mm | 493 mm | |
Weight | 8.7 kg | |
Noise (sound pressure level) in dBA at 50 Hz or 1500 rpm/62% (VARIO)/1500 rpm (VARIO-SP)/12500 Upm (VACUU·PURE®) | 42 dBA | |
NRTL certification | Yes | |
Items supplied | Pumping unit completely mounted, ready for use, with manual. | |
Rated mains voltage range 1 | 200-230 V | |
Rated mains voltage range 2 | 100-120 V | |
Mains frequency 1 | 50-60 Hz | |
Mains frequency 2 | 50-60 Hz | |
Interface | Ethernet (RJ45): Modbus TCP / USB (Type A): Data transfer, software update, RS-232 (additional adapter required) |
für Zoom klicken
Max. pumping speed 50 Hz
für Zoom klicken