Set DCP 3000 + VSP 3000Vacuum gauge

Overview

  • vacuum measuring device for connecting external vacuum sensors for measurements directly on the system
  • flexible and expandable with up to eight sensors, four of the types VSK 3000 / VACUU·VIEW (Atm. to 0.1 mbar) and VSP 3000 / VACUU·VIEW extended (Atm. up to 10-3 mbar)
  • relative pressure measurement with reference sensors (VSK 3000) and data logger function with up to 32000 measuring points (RS 232C)
  • robust plastic / ceramic vacuum sensor VSP 3000 with high chemical resistance
  • VSP 3000 with a wide measuring range from atmospheric pressure to fine vacuum (10-3 mbar) thanks to the thermal conductivity measuring principle
Cat. No.
20683190
Upon Request $2,540.00
- +

Inquire

Vacuum gauge in action

The fully electronic vacuum measuring device DCP 3000 is both versatile and decisive with its mechanical robustness, measuring accuracy and reliability. The large, illuminated display provides the measured value display of all connected sensors via an easy-to-use rotary control. Up to eight vacuum sensors (four of each type VSK 3000 / VACUU·VIEW and VSP 3000 / VACUU·VIEW extended) can be connected to the DCP 3000. The measurement can be carried out directly on the application. The DCP 3000 enables a relative pressure measurement (reference sensor VSK 3000) as well as working with pressure-dependent switching points by specifying switch-on and switch-off points on an external valve. The vacuum measuring device can also be used as a data logger with up to 32,000 measuring points. The data is read out via the serial interface (RS 232C). The vacuum sensor VSP 3000 is based on the gas thermal conductivity (Pirani) principle for the wide measuring range from atmospheric pressure to 10-3 mbar. Thanks to its structure made of chemically resistant plastics (PBT, PUR) and ceramics, it offers significantly higher chemical resistance and robustness compared to conventional Pirani sensors with fine wire metal filaments. Please also note our alternative product VACUU·VIEW extended.

für Zoom klicken

Technical data and graphs

Upper measuring limit in mbar/hPa 1000 mbar
Upper measuring limit in torr 750 torr
Lower measuring limit in mbar/hPa 1 x 10-3
Lower measuring limit in torr 1 x 10-3 torr
Measurement principle Thermal conductivity (Pirani), chemically resistant plastics / ceramics
Accuracy of measurement +- 15% of indicated value in the range 0.01-5 mbar/hPa/torr mbar/hPa/torr
Vacum connection Small flange KF DN 16 and hose nozzle DN 6/10 mm
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Max. media temperature for continuous operation 40 °C
Max. media temperature short term 80 °C
Material of outer housing Robust plastic housing with good chemical resistance
Protection class IEC 60529 IP 20
Protection class UL50E Type 1
Protection class front side IEC 60529 IP 42
Weight 0.44 kg
Dimension L in mm 144 mm
Dimension B in mm 124 mm
Dimension H in mm 114 mm
Vacuum sensor VSP 3000
Cable length of vacuum sensor 2 m
Cable length connection in m 2 m
NRTL certification Yes
Items supplied Vacuum gauge with external vacuum sensor VSP 3000, ready for operation, with wall-plug power supply and manual.
Interface RS 232C

Downloads

Vacuum gauge DCP 3000 complete withleads and gauge head VSP 3000, Pirani,certification (NRTL): C/US100-230 V/50-60 Hz,plug CEE/CH/UK/US/AUS
Set DCP 3000 + VSP 3000 Vacuum gauge
Safety information for vacuum equipment
Manual PDF 5.4 MB
Multilingual Download
Manual vacuum gauge / controller
Manual PDF 1.9 MB 1.8 MB 2 MB
Download Download Download
Technical data sheet
Data sheet PDF 3.6 MB 3.6 MB 3.6 MB 3.6 MB 3.6 MB
Download Download Download Download Download

Related Products

Vacuum gauge in action

The fully electronic vacuum measuring device DCP 3000 is both versatile and decisive with its mechanical robustness, measuring accuracy and reliability. The large, illuminated display provides the measured value display of all connected sensors via an easy-to-use rotary control. Up to eight vacuum sensors (four of each type VSK 3000 / VACUU·VIEW and VSP 3000 / VACUU·VIEW extended) can be connected to the DCP 3000. The measurement can be carried out directly on the application. The DCP 3000 enables a relative pressure measurement (reference sensor VSK 3000) as well as working with pressure-dependent switching points by specifying switch-on and switch-off points on an external valve. The vacuum measuring device can also be used as a data logger with up to 32,000 measuring points. The data is read out via the serial interface (RS 232C). The vacuum sensor VSP 3000 is based on the gas thermal conductivity (Pirani) principle for the wide measuring range from atmospheric pressure to 10-3 mbar. Thanks to its structure made of chemically resistant plastics (PBT, PUR) and ceramics, it offers significantly higher chemical resistance and robustness compared to conventional Pirani sensors with fine wire metal filaments. Please also note our alternative product VACUU·VIEW extended.

für Zoom klicken

Technical data and graphs

Upper measuring limit in mbar/hPa 1000 mbar
Upper measuring limit in torr 750 torr
Lower measuring limit in mbar/hPa 1 x 10-3
Lower measuring limit in torr 1 x 10-3 torr
Measurement principle Thermal conductivity (Pirani), chemically resistant plastics / ceramics
Accuracy of measurement +- 15% of indicated value in the range 0.01-5 mbar/hPa/torr mbar/hPa/torr
Vacum connection Small flange KF DN 16 and hose nozzle DN 6/10 mm
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Max. media temperature for continuous operation 40 °C
Max. media temperature short term 80 °C
Material of outer housing Robust plastic housing with good chemical resistance
Protection class IEC 60529 IP 20
Protection class UL50E Type 1
Protection class front side IEC 60529 IP 42
Weight 0.44 kg
Dimension L in mm 144 mm
Dimension B in mm 124 mm
Dimension H in mm 114 mm
Vacuum sensor VSP 3000
Cable length of vacuum sensor 2 m
Cable length connection in m 2 m
NRTL certification Yes
Items supplied Vacuum gauge with external vacuum sensor VSP 3000, ready for operation, with wall-plug power supply and manual.
Interface RS 232C

Downloads

Vacuum gauge DCP 3000 complete withleads and gauge head VSP 3000, Pirani,certification (NRTL): C/US100-230 V/50-60 Hz,plug CEE/CH/UK/US/AUS
Set DCP 3000 + VSP 3000 Vacuum gauge
Safety information for vacuum equipment
Manual PDF 5.4 MB
Multilingual Download
Manual vacuum gauge / controller
Manual PDF 1.9 MB 1.8 MB 2 MB
Download Download Download
Technical data sheet
Data sheet PDF 3.6 MB 3.6 MB 3.6 MB 3.6 MB 3.6 MB
Download Download Download Download Download

Related Products